Flange load cell for for rollers with bearings on one end PD 27

Product information

  • Flange load cell with a nominal measuring force of 60 N for mounting on rollers with bearings on one end
  • Precise web tension measurement independent of the force applied to the roller
  • Highly reliable in operation thanks to overload protection up to 10 times the nominal measuring force
  • For measurements in a horizontal direction, the weight of the roller does not affect the measured result
  • Nominal characteristic value calibrated in the factory to 1 mV/V
Nominal measuring force FN 60 N
Mechanical stop 1.5 x FN
Operating load 1.0 to 1.4 x FN
Limit load 10 x FN
Max. permissible axial lateral force0.5 x FN
Nominal measuring deflection 0.3 to 0.4 mm
Accuracy class 0.5
Resolution1:25
Nominal characteristic value (sensitivity) 1 mV/V
Characteristic value tolerance 0.20%
Combined error< 0.5 %
Measuring principle DMS full bridge
Nominal resistance of the DMS bridge 700 Ohm
Bridge supply voltage
Nominal value 10 V
Max. permissible value14 V
Output voltage
Nominal value range 0 to 10 mV (for nominal force and bridge supply voltage 10 V)
Maximum range 0 to 15 mV (for 1.5 x nominal force and bridge supply voltage 10 V)
Nominal/ambient temperature -10 to +60 °C
Usage temperature -10 to +90 °C
Storage temperature-10 to +90 °C
Temperature coefficient
of the characteristic value ±0.3 % / 10 K
of the zero signal ±0.3 % / 10 K
Protection class IP 54
Weight3.3 kg

Request available downloads

We will immediately send you all available documents for the components and systems.

*Required field

Order & offer

Spare parts & accessories

Contact

Write to us! We are looking forward to your message.

Salutation
*Required field